Guidance 4D probe; identify the probe via the ID code; swap the 4D push sign through the  electrical relay to generate the 4D probe function normally. four.two.two Key board The primary board might be divided into two sections: front-close of the key board and again-close of the main board.

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat element login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

three. Click on the higher icon inside the screen (prompts “Update” if you place the cursor on it), the update action is carried out, if fails, make sure you send out to R&D center. Determine 6-1 Main Watch Routine maintenance Screen 4. Following update is prosperous, restart the machine after electrical power off to generate the information successful. HDD Partition ... Web site ninety one structured report associated information file and DICOM viewing application Report report template obd.bin OBD info file version.txt Variation file Comment Comment file AnatomyImage Anatomical photos Measurement Measurement library Doppler plan and related boot configuration most important file and plug-ins, remote desktop server Multilanguage string file exe videoplay.

This handbook could referring to info shielded by copyright or patents and will not Express any license underneath the patent legal rights or copyright of Mindray, or of Many others. Webpage 9: Assertion

Simply click Agree and Carry on to accept cookies and go straight to the positioning or click Additional information to check out specific descriptions of the kinds of cookies and select regardless of whether to just accept sure cookies while on the positioning.

Mindray’s new generation of black & white ultrasound method, DP-50 Pro, is provided with Superior imaging technologies enabling further penetration and faster image acquisition with greater resolution.

The chapter provides the tactic to verify main purpose and functionality of solution. This is only utilized for reference, not preventive execution. Functionality checking and testing of the section shall be carried out by Mindray company engineers as well as the person together. Website page sixty six: General Exam

Discover improved diagnostic details by means of extended view on the anatomical structure on all convex probes.

iZoom™ enables precise viewing of graphic from length iWorks™ Protocol aids standardize workflow and cut down Test instances

five.2.three Geometric positioning accuracy Longitudinal geometric positioning accuracy  Examination Phase: Do changes as the best way in tests the maximum depth. History the gap by 20mm Every single section around the Dp50rb longitudinal targets line utilizing the measurement caliper; Find the worth with the best mistake (to 20mm), determine the accuracy utilizing the components under The measurement caliper needs to be positioned in the higher fringe of the goal, NOTE:... Website page seventy nine Transverse geometric positioning accuracy  Examination Step: Deal with the scan surface on the phantom with h2o or couple gel, gently Call the probe Together with the scan floor Change the depth, creating the transverse targets being exhibited within the picture. Change the main target stage for being posited beside the transverse targets (the regular is just not apparent) Adjust parameters like attain, TGC, creating Just about every transverse targets to generally be Evidently shown. Site 80 5.five.two.four Blackout Area Check Stage: Go over the scan surface from the phantom with h2o or few gel, gently contact the probe Using the scan area Change the depth at a lower price, and established the focus at the closest location to the scan surface. Minimize the worth of parameters like AP, Attain right until the qualifications sound just may be found. Site eighty one: Software package Improve And Servicing

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

.. Site 161 The indicator within the printer Errors arise when the adapter turns orange, along with the printing printer adapter operates. Disconnect and link the fails. energy adapter, electrical power around the printer adapter yet again, and verify whether the printing is normal right after 1 minute. Web page 163: Electrical Basic safety Inspection

Observe: Prior to inserting the connector into the probe port, inspect the connector pin. When the pin is bent, usually do not utilize the probe until finally it has been inspected / repaired / replaced. Setting up Peripherals For your designs from the supported peripherals, remember to refer to “2.

Mindray respects your privateness. We use cookies for several different functions, including Internet site features, increasing your working experience of our Site, making integration with social media marketing and serving to target our promoting.

Return to the process preset interface. The choice position alterations into Uninstalled. The uninstalling function is distinctive to interior customers.

Report this page